6, 12, 24 |
DC voltage: ±13.8mV, ±27.6mV, ±69.0mV, ±200mV, ±500mV, ±2V,±5V, ±10V, ±50V, ±50V
DC current: Max 50mA by external shunt resistor (100Ω, 250Ω) (sold separately)
Thermocouples: K, E, J, T, R, S, B, N, U, L, W-WRe26, WRe5-WRe26, PtRh40-PtRh20, NiMo-Ni, CR-AuFe, Platinel, Au/Pt
Resistance thermometers: Pt100, old Pt100, JPt100, Pt50, Pt-Co |
|
1 second/6 points, 2 seconds/12 points, 2 seconds/24 points |
About 1/40,000 or better (converted to reference range) |
At ambient temperature:23℃±10℃
K, E, J, T, N Platinel---±0.5℃ or EMF 20μV, whichever greater
Other than above---±1.0℃ or EMF 40μV, whichever greater |
Burnout detection function for thermocouple input and RTD input. Upper burnout, lower burnout or burnout disabled is selectable for each input. |
30V AC/60V DC |
130dB or more (50/60Hz) |
50dB or more (50/60Hz) |
Removable when wiring |
LCD bar graph 180mm |
Monographic type LCD (Backlight AUTO / Always ON settable) Dots : 264 x 48 dots Display area : 184 x 22mm |
All channels simultaneous display, year/month/day, hour/minute, alarm activate channel, chart speed display of measuring value. |
REC, CARD, ALM |
Status display "ALM" flash, measuring value flash at operation screen |
Absolute alarm, differential alarm, rate-ofchange alarm, FAIL, calendar timer, chart end |
Individual settings, Max 4 levels/channel |
Mechanical relay 2, 6, 12, 24 points ('a' contact)
Mechanical relay 4, 8, 16 points (‘c’ contact) |
EN61326-1
EN61010-1
*Under EMC test condition, variation in indication value is ±20% or ±2mV at maximum, whichever is larger. |
UL61010-1 2nd edition |
CAN/CSA C22.2 No.61010-1-04 |
IEC 60529 IP54 |
5 seconds/point, 2.5 seconds/point
Interlock to chart speed |
Wire-dot type 6-color ribbon |
|
Fan-fold type
Total width 200mm, total length 20m, effective chart width 180mm |
1 to 1500mm / h, in 1mm/h increments (12.5mm / h can be set exceptionally) |
Digital printing is added to trace printing at month / day, time, channel no., data, unit Interval (hour/time) arbitrary setting |
When required, interrupt trace printing and digital print time and measuring value |
Alarm activated --- Time, channel no., alarm type and level
Alarm reset --- Time, channel no., alarm level Memory capacity --- Max. 48 data |
When required, interrupt trace printing and print date, chart speed and setting information of each channel |
Print when required Up to 15 characters/message, register up to 20 characters |
Select ON / OFF of display per each channel, trace recording to chart, digital recording to chart, recording to SD card |
Record difference between reference channel and measuring value or between reference value (set value) and measuring value |
2 / 3 / 4 divisions |
Range limit is made non-linear and specific chart recording lower/upper limit is shrunk or expanded |
Recording range is shifted automatically to another set range when measured value exceeds the current range. Overlap function available |
No display or printing of channels of which ranges are not set |
100 to 240VAC, 50/60Hz |
Max 65VA
100V AC balanced: 22VA
240V AC balanced: 31VA |
Ambient temperature range: 0 to 50ºC (20 to 65%)
Ambient humidity range: 20 to 80%RH (5 to 40ºC)
Power voltage:90 to 264V AC
Power frequency:50/60Hz ±2%
Attitude: forward tilting 0º, backward tilting 0 to 30º, left/right 0 to 10º |
Door --- Aluminum die-casting
Front panel --- Glass
Case --- Cold-rolled steel plate |
Door--- Black (equivalent of Munsell N3.0)
Glass--- Clear and colorless
Case --- Gray (equivalent of Munsell N7.0) |
Panel mounting |
About 7.6kg |
Power terminal, Protective conductor terminal --- M4.0
Measuring input terminal, alarm output terminal
Remote contact terminal --- M3.5
Communication terminal --- M3.0 |
By external relay contact signal (digital contact: short or open), you can select chart speed or data printing
Input points: 5 points, 10 points, 20 points
Input signal: Digital contact signal or open collector signal
Exterior output: 5V DC/2mA
Function: 1. Record start/stop
2. Chart speed 3-speed switch
3. Data printing
4. List printing
5. Message printing
6. Operation record (Record ON/OFF condition to the designate location by bar line)
7. Integration/F value reset
8. Memory card (record start/stop)
9. Alarm output rest
10.Time correction |
Mechanical relay ('a' contact) 2 points, 6 points, 12 points, 24 points
Max. load 100 to 240VAC 0.2A 30V DC 0.2A
Min. load 5V DC 10mA
Mechanical relay ('c' contact) 4 points, 8 points, 16 points
Max. load 100 to 240VAC 0.2A 30V DC 0.2A
Min. load 5V DC 10mA |
RS232C, RS422A, RS485, Ethernet |
|