The C015 series is adjacent measuring thermocouples designed for measurement of surface temperature of moving or rolling materials, such as heating rollers, press rollers and running sheets. The thermocouple has the built-in automatic correction circuit for the difference between surrounding air and actual temperature of an object. No emissivity compensation to an object surface like as radiation thermometers is necessary.
Non-cotact measurement for lower temperature ranges |
Unique circuit for temperature correction |
Stability of measurement by stabilizing filter |
Affection free from emissivity |
Thermoelectric voltage of Type K thermocouple is applied as output. |
Models | Types | Measuring ranges | Extension wire length | Applications |
C015-11 | Standard | Room temp. to 250°C |
5m |
For no disturbance and stable measurement distance of 1 to 2mm |
C015-21 | Room temp. to 250°C |
10m |
||
C015-31 | Room temp. to 500°C |
5m |
||
C015-41 | Room temp. to 500°C |
10m |
||
C015-12 | With reflection plate | Room temp. to 250°C |
5m |
For much disturbance or measurement distance of about 3mm needed |
C015-22 | Room temp. to 250°C |
10m |
||
C015-32 | Room temp. to 500°C |
5m |
||
C015-42 | Room temp. to 500°C |
10m |
||
C015-13 | With distancer | Room temp. to 250°C |
5m |
For measurement distance fluctuated |
Element | Type K thermocouple |
Wire diameter | Φ0.1mm |
Accuracy rating |
Within ±5°C at 200°C span (For the correction constants are determined at the middle of measurement range.) |
Measurement distance | 1 to 2mm (constant) |
Measurement width | Minimum 30mm |
Response time | About 6 seconds (time constant) |
Output signal | Thermal EMF of Type K thermocouple |
Output impedance | 15 to 22Ω |
Output stabilizing filter | 0.07mm thick , amber mica |
Lead wire | Φ7mm heat resistance vinyl cord or silicon rubber lead wire 5m (19m) attached |
Performance Specification Sheet | Surface Temperature Sensors | C015 | Download |