The NC series solidpak thermocouples are the high performance thermocouples that feature high sensitivity, solidity, and durability required in a general industrial sensor. The gap between a protective tube and a thermocouple wire is densely filled with magnesium oxide. The thick protective tube provides excellent response along with vibration resistance and impact resistance. In addition, it allows the thermocouple to withstand long-term continuous operation in hot and unfavorable environment.
Quick response. |
Excellent heat resistance and corrosion resistance. |
Excellent vibration resistance and impact resistance. |
Easy-to-use terminal head. |
Element | Type Kthermocouple |
Class | JIS 1 (class 0.4),JIS 2 (class 0.75) |
Protective tubematerial | SUS304, SUS316,SUS310S, SUH446 (Sandvik P4), 253MA |
Protective tubeouter diameter (Element diameter) |
Φ1.0mm), Φ15mm (Φ1.6mm), Φ22mm (Φ3.2 mm) |
Protective tubelength | Up to 2000 mm |
Top shape | Closednon-grounding type |
Insulationmaterial | High puritymagnesium oxide (MgO) |
2-element typeprotective tube diameter (Element diameter) | Φ10mm |
Normal working limit | ||||
Thermocouple | Protective tube materials | Outer diameter | ||
Φ10mm | Φ15mm | Φ22mm | ||
K | SUS304 | -- | 1000°C | 1000°C |
SUS316 | 900°C | 1000°C | 1000°C | |
SUS310S | 1150°C | 1150°C | 1200°C | |
SUH446 | -- | -- | 1200°C | |
Sandvik 253MA | -- | -- | 1200°C |
Response time (From 0°C to 100°C boiling water) | ||
Protective tube materials | Response time | |
63.2% | 90% | |
Φ10mm | 8 seconds | 17 seconds |
Φ15mm | 11 seconds | 21 seconds |
Φ22mm | 16 seconds | 32 seconds |
Performance Specification Sheet | Solidpak Thermocouples | NC Series | Download |