This system utilizes a CCD camera, which has sensitivity at 1.0µm and Image Processing Unit that provides an image and converts video signal from the camera into temperature information. The special high temperature optics lens array system can be inserted through a small insertion port on many types of furnaces. The Image Processing Unit has an 8.3” LCD touch panel that displays wide-angle image and temperature information. It also provides the capability of up to 40 points of Contact Inputs/Outputs as well as 32 points of Analog Outputs through an external I/O unit.
Download Application check sheet
Temperature Measurement Type and Video Monitoring Type are available |
Protective tube 360, 500, 680, 900 and 1100mm length for various application |
Retracting system for safety (Accessory) |
Water+Air Cooling for high temperature application |
Model | Lens Type | Cooling System | Monitoring System |
CPA-R00S⬚⬚-WNN | 100°Lens | Water & Air Cooling | Temperature Measurement Type |
CPA-R60S⬚⬚-WNN | 60°Lens | ||
CPA-R45S⬚⬚-WNN | 45°Lens | ||
CPA-R00S⬚⬚-ANN | 100°Lens | Air Cooling Only | Temperature Measurement Type |
CPA-R60S⬚⬚-ANN | 60°Lens | ||
CPA-R45S⬚⬚-ANN | 45°Lens | ||
CPA-R00S⬚⬚-WNC | 100°Lens | Water & Air Cooling |
Video Monitoring Type Temperature measurement is not available |
CPA-R60S⬚⬚-WNC | 60°Lens | ||
CPA-R45S⬚⬚-WNC | 45°Lens | ||
CPA-R00S⬚⬚-ANC | 100°Lens | Air Cooling Only |
Video Monitoring Type Temperature measurement is not available |
CPA-R60S⬚⬚-ANC | 60°Lens | ||
CPA-R45S⬚⬚-ANC | 45°Lens | ||
⬚⬚: Array Length 04: 360mm 05: 500mm 07: 680mm 09: 900mm 11: 1100mm |
|||
Model | Description | ||
CPG-GMPR | Image Processing Unit | ||
CCZ-ZRP | Camera Power Supply Box | ||
CPY-ZRC⬚⬚ (5m, 10m and 25m are available) | Custom Cable | ||
CPY-ZRB⬚ (1, 2 or 3) | Video Input Cable | ||
CPY-ZRX | Video Input Box | ||
Retracting System |
Lens Array and Camera Unit | |
Viewable Angle | H96" x V70" (100º Lens) |
Wavelength | 0.8 to 1.0µm |
Temp Range | 700º to 2500ºC (Assignable Span:200º to 500ºC) |
Monitoring Method | Standard - Monitoring on Output - Provides Analog Color signal |
Accuracy | ±1% at Full Scale (Black Body) |
Image Processing Unit | |
Camera Control | Up to 3 Cameras |
Display | 8.4" Color LCD (Touch Panel) |
External Input/Output |
Contact Output: Max 40 points (w/ Optional I/O unit) Contact Input: Max 40 points (w/ Optional I/O unit) Analog Outpu: Max 32 points (w/ Optional I/O unit) |
Analyzing Function |
Spot: 16 spots Line: 32 lines Area: 32 areas Filter: Binalize/Pixel/Edge |
Operational Condition |
Temperature: 0 to 45°C Humidity: 20 to 85%RH (Non Condensation) |
Protective Structure | IP65 Compliant (Front Panel) |
External I/O Unit (Optional) | |
AC/DC Power Supply Unit | 100 - 120V AC |
I/O Controller Module | For connecting Processing Unit and I/O Module |
Digital I/O Module | 8 In/8 Out per Module, Up to 4 Modules |
Analog Output Module | 4 Outs per Module, Up to 8 Modules |
This software is to display thermal image data that has been saved on the processing unit. The data can be transferred from the processing unit via USB memory stick. The interface and appearance on the display are the same as the processing unit, therefore you can also change/manage Settings File and System Setup.
This package software is to support large amount of data logging and analysis via LAN connection.