top

Thermal Imaging

img

CPA-R Relay Lens Type Furnace Monitoring Camera

This system utilizes a CCD camera, which has sensitivity at 1.0µm and Image Processing Unit that provides an image and converts video signal from the camera into temperature information. The special high temperature optics lens array system can be inserted through a small insertion port on many types of furnaces. The Image Processing Unit has an 8.3” LCD touch panel that displays wide-angle image and temperature information. It also provides the capability of up to 40 points of Contact Inputs/Outputs as well as 32 points of Analog Outputs through an external I/O unit.

Download Application check sheet

Temperature Measurement Type and Video Monitoring Type are available
Protective tube 360, 500, 680, 900 and 1100mm length for various application
Retracting system for safety (Accessory)
Water+Air Cooling for high temperature application

 

 

Model Lens Type Cooling System Monitoring System
CPA-R00S⬚⬚-WNN 100°Lens Water & Air Cooling Temperature Measurement Type
CPA-R60S⬚⬚-WNN 60°Lens
CPA-R45S⬚⬚-WNN 45°Lens
CPA-R00S⬚⬚-ANN 100°Lens Air Cooling Only Temperature Measurement Type
CPA-R60S⬚⬚-ANN 60°Lens
CPA-R45S⬚⬚-ANN 45°Lens
CPA-R00S⬚⬚-WNC 100°Lens Water & Air Cooling Video Monitoring Type
Temperature measurement is not available
CPA-R60S⬚⬚-WNC 60°Lens
CPA-R45S⬚⬚-WNC 45°Lens
CPA-R00S⬚⬚-ANC 100°Lens Air Cooling Only Video Monitoring Type
Temperature measurement is not available
CPA-R60S⬚⬚-ANC 60°Lens
CPA-R45S⬚⬚-ANC 45°Lens
⬚⬚: Array Length
04: 360mm
05: 500mm
07: 680mm
09: 900mm
11: 1100mm
Model Description
CPG-GMPR Image Processing Unit
CCZ-ZRP Camera Power Supply Box
CPY-ZRC⬚⬚ (5m, 10m and 25m are available) Custom Cable
CPY-ZRB⬚ (1, 2 or 3) Video Input Cable
CPY-ZRX Video Input Box
Retracting System

 

 

Lens Array and Camera Unit
Viewable Angle H96" x V70" (100º Lens)
Wavelength 0.8 to 1.0µm
Temp Range 700º to 2500ºC (Assignable Span:200º to 500ºC)
Monitoring Method Standard - Monitoring on Output - Provides Analog Color signal
Accuracy ±1% at Full Scale (Black Body)
Image Processing Unit
Camera Control Up to 3 Cameras
Display 8.4" Color LCD (Touch Panel)
External Input/Output Contact Output: Max 40 points (w/ Optional I/O unit)
Contact Input: Max 40 points (w/ Optional I/O unit)
Analog Outpu: Max 32 points (w/ Optional I/O unit)
Analyzing Function Spot: 16 spots
Line: 32 lines
Area: 32 areas
Filter: Binalize/Pixel/Edge
Operational Condition Temperature: 0 to 45°C
Humidity: 20 to 85%RH (Non Condensation)
Protective Structure IP65 Compliant (Front Panel)
External I/O Unit (Optional)
AC/DC Power Supply Unit 100 - 120V AC
I/O Controller Module For connecting Processing Unit and I/O Module
Digital I/O Module 8 In/8 Out per Module, Up to 4 Modules
Analog Output Module 4 Outs per Module, Up to 8 Modules

 

 

Example

 

CPY-ZFP011 - Display/Setup Software (offline use)

This software is to display thermal image data that has been saved on the processing unit. The data can be transferred from the processing unit via USB memory stick. The interface and appearance on the display are the same as the processing unit, therefore you can also change/manage Settings File and System Setup.

 

 

 

 

CPY-ZFP002 - Data Logging/Analysing Software

This package software is to support large amount of data logging and analysis via LAN connection.

 