JW Series is compact lightweight three-phase control thyristor regulators enabling high-density instrumentation. The methods of control are divided into two ways, the phase control and zero-cross control. In the phase control systems, a type with the voltage, current and power feedback control types and a type without those feedbacks are available according to the characteristics of a heater used. JW Series are also capable of advanced three-phase control based on 6-arm control and fine control setting from the setting communication unit. Furthermore, remote control and data monitoring is available by connecting to a host unit.
Compact all-in-one configuration |
Setting communication unit is included |
Heater disconnection alarm and current limit are included as a standard |
Controllability is improved with 6-arm control |
Imbalanced alarm function equipped as standard |
Various protective functions |
Model (200V AC) | Model (400V AC) | Rated Current |
JW20010�N00� | JW40010�N00� | 10A |
JW20020�N00� | JW40020�N00� | 20A |
JW20030�N00� | JW40030�N00� | 30A |
JW20050�N00� | JW40050�N00� | 50A |
JW20075�N00� | JW40075�N00� | 75A |
JW20100�N00� | JW40100�N00� | 100A |
JW20150�N00� | JW40150�N00� | 150A |
JW20200�N00� | JW40200�N00� | 200A |
JW20250�N00� | JW40250�N00� | 250A |
JW20300�N00� | JW40300�N00� | 300A |
JW20400�N00� | JW40400�N00� | 400A |
JW20500�N00� | JW40500�N00� | 500A |
JW20750�N00� | JW40750�N00� | 750A |
JW20X00�N00� | JW40X00�N00� | 1000A |
Phase | Three-phases |
Rated voltage |
200V AC(200V/ 220V/ 240V selectable by switch) 400V AC(380V/ 400V/ 440V selectable by switch) to be specified ( main circuit power supply and control circuit power supply are common) * The models which have a different main circuit power supply and a control circuit power supply are manufactureable. |
Rated current | 10A, 20A, 30A, 50A, 75A, 100A, 150A, 200A, 250A, 300A, 400A, 500A,750A, 1000A to be specified |
Rated frequencies | 50/60 Hz (automatic change) |
Control system | Phase angle firing system and zero-crossing firing system |
Feedback types | Voltage, current, power feedback |
Control input signal |
4 to 20mA DC( input resistance is approx. 100Ω ) 1 to 5V DC( input resistance is approx. 50kΩ ) |
Current limit | 0 to 100 %of output range |
Output range | 0 to 98 % of supplied power voltage |
Applicable load |
Resistive load, inductive load, density 1.2 T or lower are recommended) |
Minimum load current | 0.5 A or more( at 98% output of rated voltage) |
Working temperature |
-10 to 55°C In case of more than 40°C it depends on the following derating performance |
Working humidity | 30 to 90 %RH, No dew-condensation |
Weight |
About 6kg for 10A and 20A About 8kg for 30A and 50A About 13kg for 75A and 100A About 22kg for 150A to 250A, About 36kg for 300 to 500A |
Performance Specification Sheet | Three Phase Thyristor Regulator | JW Series | Download |